3. Specifications
IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2
a. DCV
Range Resolution Accuracy Impedance
40V 0.01V ±0.75% of reading, 10M
400V 0.1V ±3 digits
600V 1V
b1. ACV (45Hz to 60Hz)
Range Resolution Accuracy Impedance
40V 0.01V ±1.0% of reading, 10M
400V 0.1V ±3 digits
600V 1V
b2. ACV (20Hz to 45Hz, 60Hz to 1KHz)
Range Resolution Accuracy Impedance
40V 0.01V ±2.5% of reading, 10M
400V 0.1V ±3 digits
600V 1V
UL 3111-1
8
2. Product Applications
Perform the following tests and/or measurements with
the 293 and the appropriate function:
HV
AC/R
ACA Heat anticipator current in thermostats.
ACV Line voltage.
ACV or DCV Control circuit voltage.
OHMS Heating element resistance (continuity).
OHMS Compressor winding resistance.
OHMS Contactor and relay coil resistance.
ACA Motor and compressor start up current.
OHMS Continuity of wiring.
Hz/FREQ Frequency on control and line voltages.
REC Record min/max voltage of controls
and line voltages.
ALL Bar graph to indicate rapid fluctuations.
ELECTRICAL
ACV Measure line voltage.
ACA Measure line current.
OHMS Continuity of circuit breakers.
DCV Voltage of direct drive DC motors.
ACA Start up current of motors, relays,
contactors and transformers.
ELECTRONIC
ACV Measure power supply voltage.
ACA Measure power supply current.
OHMS Continuity of circuit breakers and fuses.
*Warning: Test Leads. Use only correct type and
overvoltage category rating.
!
Vista de página 7