Diode Test
Test Current Over Load Protection
1.5mA MAX 250 V DC or AC RMS
Continuity Buzzer
Test Voltage Threshold Over Load Protection
3V <35Ω 250 V DC or AC RMS
Non-Contact Voltage (NCV)
Detection Range: 24VAC and above
Temperature (K-Type thermocouple)
Range Res. Accuracy
-30ºF to 1000ºF 1ºF +
(2ºF) 32.0ºF to 120ºF
+ (1%+2ºF) -3ºF to 749ºF
+
(2%+1.5ºF) 750ºF to 1000ºF
+ (2%+4ºF) -40ºF to -4ºF
Overload Protection: 60VDC or 30VAC RMS
**Celsius version of the 275 is available
11
10
Capacitance
Range Res. Accuracy
11nF 0.001nF
±(3% of reading +5 digits)
110nF 0.01nF
1.1uF 0.0001uF Overload Protection:
11µF 0.001µF 500VDC or AC RMS
110µF 0.01µF
1.1mF 0.0001mF
11mF 0.001mF
110mF 0.01mF
±(7% of reading +5 digits)
nF= nanofarad, µF= microfarad, mF= millifarad
General
Max Voltage between any 600V
input and ground
Fuse Protection (
µµ
A range) 0.5A/600V
Display Type 4000 Count 41 seg. bargraph
Operating Temperature 32ºF to 104ºF (0ºC to 40ºC)
Storage Temperature 14ºF to 122ºF (-10ºC to 50ºC)
Relative Humidity 80% non-condensing
Power Supply 9V (MN1604)
Battery Life 80 hrs. typical
Size (H x L x W) 32.5mm x 255mm x 65mm
(1.3in x 10in x 2.5in)
Weight 363g (0.8lbs)
Warning: Use only correct type and overvoltage
category rated test leads. Remove the
temperature probe when using the test
leads or amp clamp.
Warning: Use only correct type and overvoltage
category rated test leads. Remove the
temperature probe when using the test
leads or amp clamp.